The Level-1 CAL product is outputted during Level-1 processing and is an internal product only. It is not available to users.
An SRAL Level-1 product contains one calibration data file containing the Level-1 calibration parameters for the calibration nominal scenario:
-
L1B_CAL1_LRM_IQ: Level-1 Point Target Response (PTR) calibration measurements in LRM mode for I, Q configuration
-
L1B_CAL1_SAR_Norm: Level-1 PTR calibration measurements in SAR mode
-
L1B_CAL1_SAR_Auto: Level-1 PTR calibration measurements in SAR mode / AGC calibration
-
L1B_CAL2_SAR_Ku: Level-1 Gain Profile Range Window (GPRW) calibration measurements – Ku-band (SAR mode)
-
L1B_CAL2_SAR_C: Level-1 GPRW calibration measurements – C-band (SAR mode)
The main parameters available for Level-1 CAL1 PTR measurements are:
-
time-tag and geo-location
-
PTR total and maximum power
-
difference of travel between the transmission and the reference lines
-
PTR main lobe width
-
PTR secondary lobes features
-
burst power and phase corrections (SAR mode only)
-
AGC correction tables (AGC calibration only).
The main parameters available for Level-1 CAL2 GPRW measurements are:
-
time-tag and geo-location
-
GPRW maximum value location
-
left side GPRW features: mean value, standard deviation, difference between minimum and maximum values, and slope of the linear regression
-
right side GPRW features: mean value, standard deviation, difference between minimum and maximum values, and slope of the linear regression
-
GPRW normalised samples.